China Ngi N6900 Programmable LCD DC Electronic Load 3000W 30A 600V with ce certificate top quality Good price

Product Description

NGI N6900 Programmable Liquid crystal display DC CZPT ctronic Load 3000W 30A 600V
N6900 Sequence Dispersed CZPT CZPT DC CZPT ctronic Load
 
Item Introduction
N6900 series is developed based mostly on NGI’s years of encounter in tests for CZPT  supply, battery, generator and supercapacitor. It is with substantial accuracy, high trustworthiness and higher cost performance.

According to the features of high voltage & CZPT DC electronic masses with sophisticated constructions, harsh operating environments, large trustworthiness demands, and inconvenient servicing, NGI has created a quantity of optimization primarily based on the worldwide CZPT d technological innovation.

Application Fields
one.Generator
2.Charging station
3.Industrial/server CZPT source
four.Communication CZPT source
5.Battery pack
6.Capacitor module
seven.Substantial existing relay
8.Power storage program

Primary Attributes
*Power range: 1-50kW
*Voltage variety: 120V/600V/1000V/1200V, CZPT ization CZPT
*Multiple security: OCP, OVP, OTP, OPP and reverse polarity warning
*Extensive MOS defense to stay away from blow-up
*Procedure modes: CC/CV/CR/CP
*Charging & discharging manage purpose, convenient for battery and super capacitor check
*Constructed-in DCIR test perform(Optional)
*Straightforward CZPT growth by rising CZPT modules
*Analog programming interface(APG), current checking interface, and distant/neighborhood set off operate
*CR/CP perform supported by components
*Brief-circuit simulation
*Transient above-power loading ability
*Higher CZPT density, minimizing place profession
*Convenient OCP check
*Dynamic manner up to 20kHz, editable rise and slide slew fee
*Editable Von/Voff, decreasing take a look at accidents
*Liquid crystal display screen for info screen CZPT admirer management
*Developed-in vehicle take a look at purpose
*Standard 19-inch 3U, CZPT for rack set up
*Dispersed design and style and adaptable CZPT modules
*A number of interaction interfaces: LAN/CAN/RS232/GPIB(optional)

Higher reliability style
N6900 series has a extensive MOS protection circuit. No issue how much MOS is destroyed, it will not trigger brief-circuit in between the positive and damaging polarity or the optimistic polarity and the manage circuit. The damage of some MOSs does not speed up the hurt of other folks, which can be utilised constantly.
By distributed layout, it is easy to substitute or add CZPT modules and is hassle-free for maintenance and CZPT expansion.
N6900 is developed with CZPT limit circuit and has CZPT response, which can stop the load from being ruined owing to above CZPT .
N6900 adopts shielding technological innovation, which has broad adaptability to harsh check surroundings, and increases the anti-interference ability.

Short-circuit simulation
N6900 sequence supports two modes for short circuit: guide and lock.

Guide: N6900 will be short-circuited when Quick button is pressed. It will end brief-circuiting when button is unveiled. Guide method is suited for debugging or R&D, avoiding measurement accidents thanks to misoperation.
Lock: N6900 will keep limited-circuiting when Short button is pressed. It will quit quick-circuiting when the button is pressed again. Lock mode is suitable for CZPT -time quick-circuit check.

Auto examination purpose
The vehicle check can be used to simulate waveform. This function can improve the check efficiency and can be attained by SEQ purpose on the menu. Up to 100 sequence files editing is supported. Every file can support fifty steps.

OCP( above present safety) check
For the duration of OCP examination, N6900 will load under CC method and check regardless of whether the DUT voltage is reduced than lower-off voltage. If lower, N6900 will document the present loading present as the check end result and shut the input to stop the check. If the DUT voltage is larger than minimize-off voltage, N6900 will enhance the loading existing until finally the DUT voltage is reduced than minimize-off voltage or it reaches the CZPT . loading present.

Remote perception to increase measurement precision
Distant sense is also know as 4-wire sense. When N6900 is functioning, it will result in a voltage fall in the leads between the DUT and terminals of N6900, which will affect the voltage measurement accuracy of the load.
When functioning underneath CV, CR and CP modes, to guarantee correct measurement, it is advised to use distant perception. In the course of remote CZPT ng, terminals S+ and S- are directly connected to the output of the DUT, reducing the voltage fall in the leads.

Charge& discharge test
Customers can set diverse conditions on the CZPT panel to satisfy their test demands. For example, when battery voltage is lower than preliminary voltage, N6900 inner counter will commence counting. The counter will end working until the battery voltage drops to minimize-off voltage.
Exhibitions

 

 For far more specifications, you should contact us.

Model N6903-a hundred and twenty-300 N6903-120-one hundred twenty N6903-600-one hundred twenty N6903-600-30
Voltage 120V 120V 600V 600V
Existing 300A 120A 120A 30A
Electricity 3000W
Min. Operating Voltage 2V@30A 2V@300A 2V@12A 2V@120A 4.5V@12A four.5V@120A four.5V@3A 4.5V@30A
CC Mode
Assortment -30A -300A -12A -120A -12A -120A -3A -30A
Setting Resolution .1mA 1mA .1mA 1mA .1mA 1mA .1mA 1mA
Setting Accuracy
(23±5ºC)
0.1%+.1%F.S.
CV Mode
Variety -12V -120V -12V -120V -60V -600V -60V -600V
Setting Resolution .1mV 1mV .1mV 1mV 1mV 10mV 1mV 10mV
Setting Accuracy
(23±5ºC)
0.05%+.05%F.S.
CP Mode
Selection 0-3000W
Setting Resolution 0.1W
Setting Accuracy
(23±5ºC)
0.5%+1%F.S.
CR Manner
Variety .01Ω~40Ω .2Ω~400Ω .02Ω~100Ω .4Ω~1000Ω .1Ω~500Ω one.9Ω~5000Ω .38Ω~2000Ω 7.5Ω~20000Ω
Setting Resolution 16bits
Setting Accuracy
(23±5ºC)
.35%+78.1mS .35%+7.81mS .35%+31.2mS .35%+3.12mS .35%+6.25mS .35%+.625mS .35%+1.5mS .35%+.15mS
Slew Rate
Present 5-300A/ms three hundred-15000A/ms two-120A/ms one hundred twenty-6000A/ms two-120A/ms a hundred and twenty-6000A/ms .5-30A/ms 30-1500A/ms
Voltage one.-50V/ms fifty-500V/ms one.-50V/ms fifty-500V/ms 5.-250V/ms 250-2500V/ms five.-250V/ms 250-2500V/ms
Power 5-300A/ms three hundred-15000A/ms two-120A/ms 120-6000A/ms two-120A/ms one hundred twenty-6000A/ms .5-30A/ms thirty-1500A/ms
Resistance 5-300A/ms 300-15000A/ms two-120A/ms one hundred twenty-6000A/ms 2-120A/ms one hundred twenty-6000A/ms .5-30A/ms thirty-1500A/ms
Accuracy (23±5ºC) (1+35%)* Setting value
Voltage Measurement
Selection -12V -120V -12V -120V -60V -600V -60V -600V
Readback
Accuracy (23±5ºC)
0.05%+.05%F.S.
Current Measurement
Variety -30A -300A -12A -120A -12A -120A -3A -30A
Readback
Accuracy (23±5ºC)
0.1%+.1%F.S.
Power Measurement
Variety 0-3000W
Readback
Accuracy (23±5ºC)
0.5%+1%F.S.
Dynamic Mode
T1&T2 .571-60ms one-60000ms .571-60ms 1-60000ms .571-60ms 1-60000ms .571-60ms 1-60000ms
Resolution 1μs 1ms 1μs 1ms 1μs 1ms 1μs 1ms
Accuracy (23±5ºC) 1μs+100ppm 1ms+100ppm 1μs+100ppm 1ms+100ppm 1μs+100ppm 1ms+100ppm 1μs+100ppm 1ms+100ppm
Others
Interface LAN/RS232/CAN
AC Input Single phase, 220V AC±10%, frequency 47Hz~63Hz
Temperature Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC
Operating Environment Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa
Net Weight Approx. 28kg
Dimension 3U, 132.5(H)*482.(W)*612.(D)mm

 

Product N6903-a thousand-ninety N6903-one thousand-thirty N6903-1200-90 N6903-1200-thirty
Voltage 1000V 1000V 1200V 1200V
Present 90A 30A 90A 30A
Energy 3000W
Min. Operating
Voltage
5V@9A 5V@90A 5V@3A 5V@30A 5V@9A 5V@90A 5V@3A 5V@30A
CC Manner
Variety -9A -90A -3A -30A -9A -90A -3A -30A
Setting Resolution .1mA 1mA .1mA 1mA .1mA 1mA .1mA 1mA
Setting Accuracy
(23±5ºC)
0.1%+.1%F.S.
CV Method
Selection -100V -1000V -100V -1000V -120V -1200V -120V -1200V
Setting Resolution 1mV 10mV 1mV 10mV 1mV 10mV 1mV 10mV
Setting Accuracy
(23±5ºC)
0.05%+.05%F.S.
CP Mode
Selection 0-3000W
Setting Resolution 0.1W
Setting Accuracy
(23±5ºC)
0.5%+1%F.S.
CR Mode
Variety .21Ω-1111Ω 4.2Ω-11111Ω .62Ω-3333Ω 12.4Ω-33333Ω .25Ω-1333Ω 5Ω-13333Ω .75Ω-4000Ω 15Ω-40000Ω
Setting Resolution 16bits
Setting Accuracy
(23±5ºC)
.35%+2.8mS .35%+.28mS .35%+.9mS .35%+.09mS .35%+2.3mS .35%+.23mS .35%+.7mS .35%+.07mS
Slew Rate
Recent one.5-90A/ms 90-4500A/ms .5-30A/ms 30-1500A/ms one.5-90A/ms ninety-4500A/ms .5-30A/ms thirty-1500A/ms
Voltage 8-400V/ms 400-4000V/ms 8-400V/ms 400-4000V/ms eight-400V/ms 400-4000V/ms 8-400V/ms four hundred-4000V/ms
Energy one.5-90A/ms 90-4500A/ms .5-30A/ms thirty-1500A/ms one.5-90A/ms ninety-4500A/ms .5-30A/ms thirty-1500A/ms
Resistance one.5-90A/ms 90-4500A/ms .5-30A/ms thirty-1500A/ms 1.5-90A/ms ninety-4500A/ms .5-30A/ms 30-1500A/ms
Accuracy (23±5ºC) (1+35%)* Setting value
Voltage Measurement
Selection -100V -1000V -100V -1000V -120V -1200V -120V -1200V
Readback
Accuracy (23±5ºC)
0.05%+.05%F.S.
Current Measurement
Selection -9A -90A -3A -30A -9A -90A -3A -30A
Readback
Accuracy (23±5ºC)
0.1%+.1%F.S.
Power Measurement
Variety 0-3000W
Readback
Accuracy (23±5ºC)
0.5%+1%F.S.
Dynamic Mode
T1&T2 .571-60ms 1-60000ms .571-60ms one-60000ms .571-60ms one-60000ms .571-60ms 1-60000ms
Resolution 1μs 1ms 1μs 1ms 1μs 1ms 1μs 1ms
Accuracy (23±5ºC) 1μs+100ppm 1ms+100ppm 1μs+100ppm 1ms+100ppm 1μs+100ppm 1ms+100ppm 1μs+100ppm 1ms+100ppm
Others
Interface LAN/RS232/CAN
AC Input Single phase, 220V AC±10%, frequency 47Hz~63Hz
Temperature Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC
Operating Environment Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa
Net Weight Approx. 28kg
Dimension 3U, 132.5(H)*482.(W)*612.(D)mm

TB 1610 tapered bushings can be employed in a assortment of industrial programs. For repairing standard and non-standard V-belts, timing smoothing wheels, sprockets, TB hubs, couplings and other components.
China Ngi N6900 Programmable LCD DC Electronic Load 3000W 30A 600V with ce certificate top quality Good price