Solution Description
BIOBASE CZPT Gas Chromatography with Column Oven and Optional FID TCD ECD FPD Detector
Solution Description
Fuel Chromatograph
Functions
* 7-inch Liquid crystal display screen suggests temperature, fuel stream andheating curve.
* Self-test perform and computerized faultrecognition function.
* 8 pcs external extension interfaces can link with control valve.
* Multi-main and 32-bit embedded components system assures the reputable procedure.
* Synchronous exterior set off operate and the exterior sign (auto sampler,thermal analyzer, etc.) can commence the equipment and workstation computer software at the very same time.
* With chromatography workstation application to approach info.
* Memory function: can keep 20 sample check modes.
* One particular important begin up purpose.
Technological Parameters
Product |
BK-GC112A |
|||
Oven |
Capability |
22L |
||
Temp. Assortment |
RT+5ºC~400ºC |
|||
Temp.Accuracy |
±0.1ºC |
|||
Temp.Software |
nine step |
|||
System Total Time |
9999.9 min |
|||
MaxTemp. Heating Price |
60ºC/min |
|||
Sample Injector |
Temp.Range |
RT+7ºC~420ºC |
||
Column or break up injector can be installed. |
||||
Carrier gasoline stream handle type: Consistent pressure method. |
||||
Max. CZPT tity |
3pcs |
|||
Pre Column Force Variety |
-400kpa |
|||
Pre Column Stress Accuracy |
.1kpa |
|||
Circulation Environment Range |
H2: -200ml/min N2: -150ml/min |
|||
Detector |
Temp.Selection |
RT+7ºC~420ºC |
||
Hydrogen Flame Ionization Detector (FID) |
Logarithmic amplifier |
|||
Higher voltage switch control |
||||
Baseline sign show |
||||
Detection limit:≤3*10-12g/s (Sample: n-hexadecane) |
||||
Baseline sound:≤5*ten-14A |
||||
Baseline draft:≤6*10-13A |
||||
Dynamic assortment: 107 |
||||
RSD:≤3% |
||||
Thermal Conductivity Detector (TCD) (Optional) |
Sensitivity: 8000mv.ml/mg (Sample: n-hexadecane) |
|||
Baseline sounds:≤0.05mV |
||||
Baseline draft:≤0.15mV/30min |
||||
Dynamic selection: one zero five |
||||
Power CZPT |
AC220V±10%, 50Hz |
|||
Common Accessory |
FID detector,Capillary injection program, Chromatography workstation software program,RS232 port, LAN port |
|||
Optional Accent |
TCD detector, Chromatographic column, Gasoline purifier. |
|||
Deal Dimensions (W*D*H) |
740*730*840mm |
|||
Gross CZPT ght |
80kg |
Gas Chromatograph
Characteristics
one. 5.7-inch Lcd display indicates temperature,time andgas stream.
two. Self-test, CZPT security, keyboard lock, automated ignition andantipower mutation interference function.
3. Can hook up with Web,realize data transfer and plan up grade immediately.
four. Equipped with a flame ionization detector (FID), and TCD, ECD, FPD, NPD are optional. Can install3 detectors at the same time.
5. Can set up packed column and capillary column at the same time
6. Double column compensation operate,which can properly restrain baseline drift and theinfluence of track record sound.
7. Large potential oven (300*280*180mm) can hold 2 pcs .32mm diametercapillary column (length: 80m).
eight. Better thermal insulation result: when the temp. of oven,vaporizing chamber and detector reach 300ºC, the max. temp. of outer chamber is 40ºC.
9. With chromatography workstation application to procedure info.
Technical Parameters
Model |
BK-GC7820 |
|
Oven |
Temp. Range |
RT~450ºC |
Temp. Accuracy |
≤±0.1ºC |
|
Temp. Software |
sixteen-period |
|
Max. Temp. Heating Charge |
40ºC/min |
|
Detector |
Hydrogen Flame Ionization Detector (FID) |
Detection restrict:≤3×10-12g/s (Sample:n-hexadecane) |
Baseline drift:≤1×10-13A/30min |
||
Linear selection:≥107 |
||
ThermalConductivityDetector (TCD) (Optional) |
Sensitivity: >10000mv.ml/mg (Sample: n-hexadecane) |
|
Linear selection:≥105 |
||
Electron Capture Detector (ECD) (Optional) |
Detection restrict:≤1×10-14g/ml (Sample:n-hexadecane δ-666) |
|
Linear assortment: ≥104 |
||
Flame Photometric Detector (FPD) (Optional) |
Detection limit:≤2×10-11g/s(S ofthiophene) Detection restrict:≤1×10-12g/s(P ofmethyl parathion) |
|
Linear range (S): ≥103 Linear range (P): ≥104 |
||
Nitrogen and Phosphorus Detector (NPD) (Optional) |
Detection limit:≤1×10-12g/s(Azobenzene) Detection restrict:≤1×10-12g/s(Marla sulfur phosphorous) |
|
Linear assortment: ≥103 |
||
Electricity CZPT |
AC110/220V±10%, fifty/60Hz |
|
Common Accessory |
FID detector, Chromatography workstation application |
|
Optional Accent |
Sample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column. |
|
Package Size (W*D*H) |
800*570*650mm |
|
Gross CZPT ght |
75kg |